OTC DAIHEN Servo Overload Alarm Guide
A servo overload alarm usually points to excess mechanical resistance, abnormal collision load, or motion components that no longer move freely under programmed speed.
This symptom guide helps prepare a support request; it is not a controller-specific alarm-code reference. Record the exact displayed code and consult the manual for the installed controller and software version.
Typical symptoms
The alarm appears during acceleration, deceleration, or a single axis posture change.
The robot may feel heavy on one axis or stop only when moving through a specific joint range.
Operators may also report recent collision marks, abnormal sound, or increased backlash.
Likely causes
Mechanical resistance from worn reducers or stressed servo motors
Unexpected external load from collision, fixture interference, or cable drag
A wrist package or tooling update that exceeds the comfortable motion margin
First checks before ordering parts
Before physical inspection, a qualified technician must follow the equipment manual and site isolation procedure. Do not reconnect components while energized or bypass safeguards.
Record the affected axis number, robot model, and the exact motion step that triggers the alarm.
Inspect the arm, cable route, and tooling for collision marks or motion obstruction.
Compare the current wrist package and workpiece load against the intended robot payload setup.
What to send when escalation is needed
Robot model, controller generation, axis number, and a short video of the motion issue
Photos of the reducer, servo area, and any impact marks around the fixture
Whether the issue started after a collision, tooling change, or maintenance intervention
Related products
Related spare parts
Servo overload FAQ
Does a servo overload alarm always mean the motor is damaged?
No. The alarm can also come from fixture collision, cable drag, wrist load changes, or mechanical resistance elsewhere in the motion chain.
What is the most useful part detail for quoting?
The robot model, affected axis number, and clear photos around the reducer or servo section normally give the fastest starting point for spare-parts screening.